MET ONE 6000P 遠程空氣粒子計數器

MET ONE 6000 空氣粒子計數器設計緊湊,具有靈活的尺寸、流量和通訊選擇,滿足製藥、半導體、硬碟驅動器和面板顯示行業中無塵室環境的特定需求,為連續的粒子監測提供 ISO 21501 標準準確度。採利用 MET ONE 6000P 遠程空氣粒子計數器的綜合多參數測量,可降低初始安裝成本。

  • 內建真空泵
  • 業界先進的粒子計數在線可靠性
  • 靈活方便,可用於所有的遠程空氣粒子計數器應用
  • 採用長壽命激光二極管,可保證連續監測
  • 容易與任何設施監控系統集成
  • 開放架構設計,可與您的系統無縫通訊
  • 計時和通知通過內建的狀態啟示燈實現通知可視化
  • 符合 21 CFR part 11,FDA cGMP 和 EU GMP Annex 1 標準

 *本產品僅供工業與科學研究使用,不用於臨床診斷 

Explore MET ONE 6000P Models

產品特性

合規標準

  • 內建流量傳感器,確保正確的空氣流量採樣
  • 0.5µm 粒子大小靈敏度制藥和 ISO 5 級無塵室監測
  • 符合 21 CFR 第 11 部分,FDA cGMP 和 EU GMP Annex 1 標准

儀器操作

  • 集成或外部狀態啟示燈幫助快速排除故障並減少停機時間
  • 流量傳感器提高了連續監測過程中的運行可靠性
  • 減少儀器拆卸和重新安裝的停機時間,用於日常校準/預防性維護

設備整合

  • 多種通訊選項,方便設備監測系統(FMS)整合
  • 內建流量傳感器控制真空幫浦,降低安裝成本和系統複雜度

實驗可靠性

  • 集成幫浦提高了整個系統的可靠性——避免故障發生
  • 長壽命雷射二極管,確保連續監測

Technical Documents

Didn't find what you are looking for? For more results click here.

FAQ on MET ONE 6000P Remote Air Particle Counter

Can the MET ONE 6000P Remote Air Particle Counter integrate with facility monitoring systems?

Yes. The MET ONE 6000P Remote Air Particle Counter provides multiple communication options and an open-architecture design for integration with an appropriate facility monitoring system. Depending on the selected configuration, the FMS can centralize particle-count data, alarms, trends, and reporting alongside other environmental information.

How does the MET ONE 6000P Remote Air Particle Counter support Annex 1 environmental monitoring programs?

The MET ONE 6000P Remote Air Particle Counter can provide continuous non-viable airborne particle data for use within a risk-based environmental monitoring program and contamination control strategy. Its 0.5 µm sensitivity, 1.0 CFM flow, flow monitoring, continuous-operation design, and particle-count alarm indication can support ongoing visibility into particle conditions at selected monitoring locations.

Is the MET ONE 6000P Remote Air Particle Counter suitable for continuous cleanroom monitoring?

Yes. The MET ONE 6000P Remote Air Particle Counter is designed for continuous remote particle monitoring. It combines an integrated vacuum pump rated for continuous use, a long-life laser diode, flow sensing, automated or remote sampling, and local status and count-alarm indication.

What is the difference between the MET ONE 6000, MET ONE 6000P, and MET ONE 7000 Air Particle Counters?

All three are fixed remote air particle counters for continuous cleanroom monitoring. Each can be connected to a facility monitoring system (FMS) to support centralized particle-data collection, alarms, trending, and reporting, subject to confirmation of the required communication protocol and system configuration.

  • MET ONE 6000 Remote Air Particle Counter: Requires an external vacuum source and offers multiple sensitivity and flow-rate options.
  • MET ONE 6000P Remote Air Particle Counter: Includes an integrated vacuum pump, simplifying installation where a centralized vacuum system is not available.
  • MET ONE 7000 Remote Air Particle Counter: Adds features for demanding aseptic and sterile environments, including wash-down protection, and local vacuum control.

What is the MET ONE 6000P Remote Air Particle Counter used for?

The MET ONE 6000P Remote Air Particle Counter is designed for continuous, fixed-point monitoring of non-viable airborne particles in cleanrooms and controlled environments. It provides 0.5 µm sensitivity at a 1.0 CFM, approximately 28.3 L/min, flow rate and incorporates a vacuum pump, making it suitable for monitoring locations where a centralized vacuum source is unavailable. When integrated with an appropriate facility monitoring system, its particle-count data can support environmental monitoring, trending, alarm management, and contamination-control activities.

Which industries commonly use the MET ONE 6000P Remote Air Particle Counter?

The MET ONE 6000P Remote Air Particle Counter is commonly used in pharmaceutical manufacturing, biotechnology, medical device manufacturing, and other environments where continuous environmental monitoring is required.

What are the benefits of a remote air particle monitoring solution?

A remote air particle monitoring solution can provide ongoing particle data from defined monitoring locations and reduce reliance on manual collection or transfer of results. When the MET ONE 6000P Remote Air Particle Counter is connected to an appropriate FMS, particle data and alarms can be centralized for trending, review, and reporting. These capabilities can support timely detection and investigation of adverse particle conditions, but regulatory compliance depends on the complete system configuration, software controls, validation, procedures, user access, record review, and quality-system implementation.